Thermometers
Thermocouple (resistance) for power station temperature measurement

以代替进口。 With the continuous development of China's power industry, various types of thermocouples (resistances) for temperature measurement of power stations suitable for power stations are urgently needed to replace imports. 增加了新的品种,使整个配套系列的品种,规格完全符合国产或引进的30万、60万千瓦发电机组以及国内其它机组的配套需要,并以优异的质量业满足市场。 Thermocouple (resistance) for power station temperature measurement has added new varieties, making the entire supporting series of varieties and specifications fully meet the supporting needs of domestic or imported 300,000 and 600,000 kilowatt generating units and other domestic units, with excellent quality Industry meets the market. zzyfwh.com

Range
category
Code
Index number
Temperature measurement range ℃
Accuracy class
Allowable deviation △ t
NiCr-NiSi
WRNT
K
0 ~ 800
± 2.5 ℃ or 0.75% t
Ni-Cr-Cu-Ni
WRET
E
0 ~ 600
± 2.5 ℃ or 0.75% t
Copper-copper nickel
WRCT
T
-40 ~ 350
± 1 ℃ or 0.75% t
Platinum resistance
WZPT
Pt100
-200 ~ 500
Class B
± (0.30 + 0.005 | t |)
Copper resistance
WZCT
Cu50
-50 ~ 100
± (0.30 + 6.0 × 10-3t)

Note: “t” is the measured temperature of the temperature sensing element. For platinum resistance and copper resistance, it is the absolute value of the temperature of the temperature sensing element.

公称压力 ● Nominal pressure of thermocouple (resistance) for power station temperature measurement

Generally refers to the static external pressure that the protective tube can withstand without breaking at normal temperature. The test pressure is generally 1.5 times the nominal pressure. In fact, the allowable working pressure is not only related to the protection tube material, diameter, and wall thickness, but also to its structural form, installation method, insertion depth, and the flow rate and type of the measured medium.

The measured current through platinum resistance does not exceed 5mA.