Flow meter
DXLZ metal tube float flowmeter

DXLZ metal tube float flowmeter

DXZ metal tube float flowmeter

Clamp type metal tube float flowmeter

Overview: LZ series metal tube float flowmeter adopts variable area as the measuring principle for measuring gas and liquid. All-metal structure, including indication type, corrosion-resistant type, electric remote transmission high voltage type, jacket type, explosion-proof type. With 0 ~ 10mA, 4 ~ 20mA standard analog signal output and field indication. Digital communication, accumulation, on-site modification of measurement parameters, and special specifications, different power supply functions. Widely used in chemical, petroleum, pharmaceutical power generation, food, water treatment, etc. Adverse environmental conditions, complex, and various media conditions during flow measurement.
Principle: In the measuring tube, as the flow rate changes, the float moves upwards, and the force F and the weight W of the float reach a balance at a certain position. At this time, the area of the circulating annulus between the float and the orifice plate remains constant. The area of the annulus is proportional to the rising height of the float, that is, the position where the float rises in the measuring tube represents the magnitude of the flow. The position of the changing float is transmitted from the internal magnet to the external indicator, so that the indicator correctly indicates the flow value at this time. This means that the indicator housing is not in direct contact with the measuring tube. Therefore, even if a limit switch or transmitter is installed, the instrument can be used under high temperature and high pressure working conditions (picture)
LZ features: measuring part: 1 measuring tube indicator with independent mnodular design
2 sturdy all-metal structure design float meter
3Select stainless steel, titanium, Hastelloy, PTFE material measurement system
4 Low pressure loss design
5 magnetic coupling structure ensures data transmission and signal more stable
6 Insulation or heat tracing jacket
7 vertical, horizontal, various installation methods are more suitable for different use occasions
LZ flowmeter can be equipped with M7, M8, M9, M10 indicators:
Magnetic coupling is used in M7. The angular displacement of the tracking magnet reflects the measured flow linearly on the scale plate by a curved plate mechanism. KW5-1 signal converter is used to accurately convert the flow value into a 0-10mA or 4-20mA current signal. Can bring the upper and lower limit alarm switch.
In the M8, M9, and M10 indicators, a piece of coupled magnetic steel is used to complete the flow indication, the electrical signal conversion and the damping function designed to control the flow fluctuation. The all-metal stainless steel case makes the instrument safer to operate, and more suitable for harsh and complex Environmental conditions.
Adopt module combination design. It can quickly add electrical signal output, on-off and off-line switches, and flow accumulation function to the instrument on the scene. Each functional unit board is a plug-in structure with simple, convenient and accurate positioning. It solves the faults caused by human factors in the old products due to human factors in various links and the defects that reduce the accuracy of the instrument after replacing parts, and the reliability of the instrument is greatly improved.
Using the latest ESK signal converter, PC and HART communicator can be used to reset the technical parameters on site.
You can choose to install in the local flow indicating instrument:
I. KW5-1 linear indication output 0-10Ma, 4-20mA standard signal (intrinsically safe type)
2. ESK signal converter with 4-20mA linear output and HART protocol without hysteresis (intrinsically safe type)
Three, with upper and lower limit alarm switchesFour, flow accumulation unit board sensor with 6-bit LED display: The sensor is also known as the measuring tube with a tapered tube or orifice guide, float, lower and upper gear, card enclosure, installation method Blue composition.

Flameproof metal tube rotor flowmeter

Intrinsically safe metal tube rotor flowmeter

Flow meter:

Float material: 1Gr18Ni9Ti 316L2PTFE

caliber Float Water 1 / h
(0.1013MPɑ ɑBs, 20 ℃) air
Air m3 / h
(0.1013MPɑ ɑBs20 ℃)
  Pressure loss Kpa (orifice) Pressure loss KPɑ (
Taper tube) (low pressure loss and business order)
   1 2 1 1 2 1 2
15 s16.0 10 - - 6.5   1.5 -
s16.1 25 - 0.7 6.5 1.5 -
s16.1ɑ 30 - 0.9 6.5 1.5 -
s16.2 40 25 1.2 6.5 1.5 1.5
s16.2ɑ 50 30 1.5 6.6 5.5 1.5 1.5
s16.3 60 40 1.8 6.6 5.5 1.5 1.5
s16.3ɑ 80 50 2.4 6.6 5.5 1.5 1.5
s16.4 100 60 2.8 6.6 5.6 1.5 1.5
s16.4ɑ 120 80 3.5 6.8 5.6 1.5 1.5
s16.5 160 100 4.5 6.8 5.8 1.5 1.5
s16.5ɑ 200 120 6.0 7.2 5.8 1.5 1.5
s16.6 250 160 7.5 7.2 6.1 3.0 1.5
s16.6ɑ 300 200 9.0 8.6 6.1 3.0 1.5
s16.7 400 250 12 8.6 6.1 3.0 3.0
s16.7ɑ 500 300 15 11.1 7.3 3.0 3.0
s16.8 600 400 18 11.1 7.3 3.5 3.0
20 * s20.1 1000 600 30 7.0 5.6 1.5 1.5
s20.2 1600 1000 45 8.0 5.6 2.0 2.0
s20.2ɑ 2000 - 60 10.8 6.1 3.5 -
25 s26.1 1000 600 30 7.0 5.9 1.5 1.5
s26.1ɑ 1200 800 35 7.0 6.0 1.5 1.5
s26.2 1600 1000 45 8.0 6.0 3.0 1.5
s26.2ɑ 2000 1200 60 10.8 6.8 3.0 1.5
s26.3 2500 1600 75 10.8 6.8 3.5 3.0
s26.3ɑ 3000 2000 90 15.8 9.2 3.5 3.0
s26.4 4000 2500 125 15.8 9.2 8.0 3.5
s26.4ɑ 5000 3000 150 16.2 10.2 8.0 3.5
s26.5 6000 - 180 16.2   16.0 -
32 * s32.1 4000 2500 120 8.0 6.8 8.0 5.0
s32.2 6000 4000 180 10.8 6.8 12.0 8.0
s32.3 8000 - 240 12.2 9.2 16.0 -
40 * s40.1 6000 4000 120 8.0 7.2 10.0 6.0
s40.2 8000 6000 180 10.2 7.2 12.0 10.0
s40.3 10000 - 240 11.0 10.2 14.0 -
50 s56.1 6000 4000 180 8.0 6.8 3.0 3.0
s56.1ɑ 8000 5000 240 8.0 6.8 3.0 3.0
s56.2 10000 6000 300 11.0 9.4 4.0 3.0
s56.2ɑ 12000 8000 360 11.0 9.4 4.0 3.0
s56.3 16000 10000 480 16.2 14.5 8.0 4.0
s56.3ɑ 20000 12000 600 16.2 14.5 8.0 4.0
65 * s65.1 16000 10000 480 8.0 6.9 6.0 6.0
s65.2 20000 16000 600 8.0 6.9 8.0 8.0
s65.2ɑ 25000 20000 750 11.0 9.5 10.0 12.0
s65.3 30000 - 900 11.0 9.5 14.0 -
s65.3ɑ 35000 - 1000 16.2 12.5 20.0 -
80 s86.1 25000 16000 750 8.2 6.9 14.0 8.0
s86.1ɑ 30000 20000 900 8.2 6.9 14.0 8.0
s86.2 40000 25000 1200 9.5 8.1 22.0 14.0
s86.2ɑ 50000 - 1500 9.5 8.1 22.0 -
100 s106.1 60000 40000 1800 8.0 9.5 30.0 25.0
s106.1ɑ 80000 50000 2400 10.0 9.2 30.0 25.0
s106.2 100000 - 3000 10.0 9.2 44.0 -
125 s126.1 100000 80000 3000 10.0 8.5 45.0 35.0
s126.2 125000 100000 - 12.2 10.1 48.0 40.0
150 s156.1 125000 100000 - 11.0 9.2 64.0 37.0
s156.2 150000 125000 - 13.2 12.1 50.0 42.0
200 s206.1 200000 150000 - 14.0 10.2 60.0 60.0
250 s256.1 300000 200000 - 16.0 10.2 60.0 60.0
Note: The relevant data in the flow meter are standard parameters of the instrument. If there is a special flow weight range. Can be negotiated with the supplier.

Selection code LZ series float / rotor flowmeter: Type definition: LZZ- means direct indicator, LZD- means remote
1 series type number selection: 1 vertical installation type 2H horizontal installation type 3LA bottom in and out installation type 4AA in and out installation type 5S back screw connection 6M quick connector connection
2 Material selection: 1 R1 ICr8Ni9Ti (stainless steel) RO OCr18No2Ti (stainless steel)
2 R4 304 stainless steel R4L 304L (stainless steel)
3 R6 316 (stainless steel) R6L 316L (stainless steel)
4 Ti titanium alloy
5 HC4 Hastellay-C4
6 F lined with PTFE (polytetrafluoroethylene)
3 indicator selection: 1 M7 linear indicator (only applicable to select K1 lower limit, K2 upper limit, or KW5-1 angle transmitter to transform into remote indicator)
2 M8 non-linear indicator (full-screen full-screen display, LCD display instantaneous / cumulative flow value), two-wire 4-20mA output, 24VDC power supply, with relay alarm point output. 3 flying lead indicator (with HART communication function, can be on-site group calibration, LCD display instantaneous / or cumulative flow value), magnetic electronic transmitter, two-wire 4-20mA output, 24VDC power supply, intrinsically safe, field machinery The hands indicate the flow scale. 4 M10 fee linear indicator with (M9) stainless steel case, sanitary type, anti-corrosion type, battery-powered
4 Explosion-proof type selection: 1 ESK intrinsically safe type indicates electrical signal 4-20mA output 2 EXD explosion-proof type indicates electrical signal 4-20mA output and accumulated flow 3 ESK-Z intrinsically safe type indicates electrical signal 4-20mA output and accumulated flow 4 KW5 -1 Intrinsically safe type means electric signal 4-20mA output
5 Measurement medium classification: 1 L liquid 2 G gas sensor Added function: 1 T insulation / cooling jacket 2 HT high temperature type indicator
7 means switch preset alarm output: 1 K1 with one alarm switch SC 3.5-NO 2 K2 with two personal alarm switches SC 3.5-NO