Flow meter
Liquid turbine flowmeter


概述 I. Overview of DXLWGY liquid turbine flowmeter
Turbine flow meters (hereinafter referred to as TUF) are the main varieties of impeller flow (velocity) meters. Impeller flow meters include anemometers and water meters. TUF consists of a sensor and a conversion display. The sensor uses a multi-blade rotor to sense the average flow velocity of the fluid, thereby deriving the flow rate or the total amount. The rotation speed (or number of revolutions) of the rotor can be detected mechanically, magnetically, and photoelectrically, and displayed and recorded by a reading device. It is said that the United States issued the first TUF patent as early as 1886, and the 1914 patent believed that TUF traffic was related to frequency. The first TUF in the United States was developed in 1938. It was used to measure the flow of fuel on aircraft. It was only after the Second World War that jet engines and liquid jet fuel urgently needed a high-precision, fast-response flowmeter to make it truly Industrial applications. Today, it has been widely used in petroleum, chemical, scientific research, national defense, and metrology departments.
Working principle of DXLWGY liquid turbine flowmeter
When the measured fluid flows through the sensor, under the action of the fluid, the impeller rotates under force, and its speed is proportional to the average flow velocity of the pipe. The rotation of the impeller changes the magnetic resistance of the magnetoelectric converter periodically. The magnetic flux in the detection coil changes periodically, generating a periodic induced potential, that is, an electric pulse signal, which is amplified by an amplifier and sent to a display instrument for display.
Product features of DXLWGY liquid turbine flowmeter
1. High accuracy, generally up to ± 1% R, ± 0.5% R, high precision type can reach ± 0.2% R;
2. Good repeatability, short-term repeatability can reach 0.05% ~ 0.2%, it is precisely because of good repeatability, such as regular calibration or online calibration can get very high accuracy, is the preferred flowmeter in trade settlement ;
3. Output pulse frequency signal, suitable for total measurement and connection with computer, no zero drift, strong anti-interference ability;
4. High frequency signal (3 ~ 4kHz) can be obtained with strong signal resolution;
5. Wide range, medium and large caliber up to 1:20, small caliber up to 1:10;
6. Compact and lightweight structure, convenient installation and maintenance, large circulation capacity;
7. Applicable for high-pressure measurement. There is no need to make holes in the meter body, and it is easy to make high-voltage meters.
8. There are many types of special-purpose sensors, which can be designed as various types of special-purpose sensors according to the special needs of users, such as low-temperature type, two-way type, downhole type, and sand mixing type;
9. Can be made into a plug-in type, suitable for large-caliber measurement, small pressure loss, low price, can be continuously removed, convenient installation and maintenance.
Fourth, DXLWGY liquid turbine flowmeter basic parameters and technical performance
1. Technical performance table 1

Instrument caliber and connection

4 ‚6‚ 10 ‚15‚ 20 ‚25‚ 32 ‚40 threaded

(15 ‚20‚ 25 ‚32‚ 40) 50 ‚65‚ 80 ‚100‚ 125 ‚150‚ 200 Flange connection

Accuracy class ± 1% R ‚± 0.5% R‚ ± 0.2% R (requires special)
Range ratio 1:10; 1:15; 1:20
Instrument material 304 stainless steel, 316 (L) stainless steel, etc.
Measured medium temperature ( ℃) -20 ~ + 120
Environmental conditions Temperature -10 ~ + 55 ℃, relative humidity 5% ~ 90%, atmospheric pressure 86 ~ 106Kpa
output signal

Sensor: pulse frequency signal, low level ≤0.8V high level ≥8V

Transmitter: Two-wire 4 ~ 20mADC current signal

Power supply

Sensor: ± 12VDC ‚± 24VDC (optional)

Transmitter: ± 24VDC

On-site display type: instrument comes with 3.2V lithium battery

Signal transmission line STVPV3 × 0.3 (three-wire system), 2 × 0.3 (two-wire system)
Transmission distance ≤1000m
Signal line interface Basic type: Hausmann connector, explosion-proof type: female thread M20 × 1.5
Explosion-proof grade Basic type: non-explosion-proof products, explosion-proof type: ExdllBT6
Protection class IP65

2. Measuring range and working pressure gauge 2

Instrument caliber

(Mm)

Normal flow range

(M³ / h)

Extended traffic range

(M³ / h)

Conventional tolerance pressure

(Mpa)

Special pressure resistance level (Mpa)

(Flange connection)

DN4 0.04 ~ 0.25 0.04 ~ 0.4 6.3 12 ‚16‚ 25
DN5 0.1 ~ 0.6 0.06 ~ 0.6 6.3 12 ‚16‚ 25
DN10 0.2 ~ 1.2 0.15 ~ 1.5 6.3 12 ‚16‚ 25
DN15 0.6 ~ 6 0.4 ~ 8 6.3 ‚2.5 (flange) 4.0 ‚6.3‚ 12 ‚16‚ 25
DN20 0.8 ~ 8 0.45 ~ 9 6.3 ‚2.5 (flange) 4.0 ‚6.3‚ 12 ‚16‚ 25
DN25 1 ~ 10 0.5 ~ 10 6.3 ‚2.5 (flange) 4.0 ‚6.3‚ 12 ‚16‚ 25
DN32 1.5 ~ 15 0.8 ~ 15 6.3 ‚2.5 (flange) 4.0 ‚6.3‚ 12 ‚16‚ 25
DN40 2 ~ 20 1 ~ 20 6.3 ‚2.5 (flange) 4.0 ‚6.3‚ 12 ‚16‚ 25
DN50 4 ~ 40 2 ~ 40 2.5 4.0 ‚6.3‚ 12 ‚16‚ 25
DN65 7 ~ 70 4 ~ 70 2.5 4.0 ‚6.3‚ 12 ‚16‚ 25
DN80 10 ~ 100 5 ~ 100 2.5 4.0 ‚6.3‚ 12 ‚16‚ 25
DN100 20 ~ 200 10 ~ 200 2.5 4.0 ‚6.3‚ 12 ‚16‚ 25
DN125 25 ~ 250 13 ~ 250 1.6 2.5 ‚4.0‚ 6.3 ‚12‚ 16
DN150 30 ~ 300 15 ~ 300 1.6 2.5 ‚4.0‚ 6.3 ‚12‚ 16
DN200 80 ~ 800 40 ~ 800 1.6 2.5 ‚4.0‚ 6.3 ‚12‚ 16


仪表分类 Five, DXLWGY liquid turbine flowmeter instrument classification
1. Classified by instrument function, DXLWGY series turbine flowmeters can be divided into 2 categories, namely:
Turbine flow sensor / transmitter
Intelligent integrated turbine flowmeter
Turbine flow sensor / transmitter
This type of turbine flow product does not have the on-site display function, and only transmits the flow signal far away. The flow signal can be divided into pulse signal or current signal (4-20mA); the instrument is low in price, high in integration, and small in size, and is particularly suitable for use with computer control systems such as secondary display instruments, PLC, and DCS.
According to different output signals, this type of product can be divided into DXLWGY- □ N type and DXLWGY- □ A type
DXLWGY- □ N type sensor: 12 ~ 24VDC power supply, three-wire pulse output, high level ≥8V, low level ≤0.8V; signal transmission distance ≤1000m;
DXLWGY- □ A type transmitter: 24VDC power supply, two-wire system 4-20mA output, signal transmission distance ≤1000.
This type of turbine flow products are divided into two types: basic and explosion-proof (ExdIIBT6). The shape is shown in Figure 3 http //: zzyfwh.com Figure 4

Basic sensor / transmitter Explosion-proof sensor / transmitter


Intelligent integrated turbine flowmeter
A new type of smart meter integrating the turbine flow sensor and display integration developed with advanced ultra-low-power single-chip microcomputer technology. It adopts dual-row LCD on-site display. It has a compact mechanism, intuitive and clear readings, high reliability, and is not subject to external power Obvious advantages such as interference, anti-lightning, and low cost. The meter has three-point correction of the meter coefficient, intelligently compensates for the non-linearity of the meter coefficient, and can be corrected on site. The high-definition liquid crystal display simultaneously displays the instantaneous flow rate (4 significant digits) and the accumulated flow rate (8 significant digits, with a clear function). All valid data will not be lost for 10 years after power off. These turbine flowmeters are all explosion-proof products with explosion-proof grade: ExdIIBT6.
This type of turbine flowmeter can be divided into DXLWGY- □ B type and DXLWGY- □ C type according to the power supply mode and whether it has remote signal output.
DXLWGY- □ B type: The power supply uses 3.2V10AH lithium battery (can run continuously for more than 4 years); no signal output function.
DXLWGY- □ C type: The power supply uses 24VDC external power supply, and outputs 4-20mA standard two-wire current signal. RS485 or HART communication can be added according to different site requirements.
Figure 5

Intelligent integrated turbine flowmeter

Six, instrument selection table 3
Type Explain
DXL

WG

Y__

public 4        4mm, standard range 0.04 ~ 0.25m³ / h, wide range 0.04 ~ 0.4m³ / h
6        6mm, standard range 0.1 ~ 0.6m³ / h, wide range 0.06 ~ 0.6m³ / h
  10        10mm, standard range 0.2 ~ 1.2m³ / h, wide range 0.15 ~ 1.5m³ / h
15        15mm, standard range 0.6 ~ 6m³ / h, wide range 0.4 ~ 8m³ / h
Weigh 20        20mm, standard range 0.8 ~ 8m³ / h, wide range 0.4 ~ 8m³ / h
25        25mm, standard range 1 ~ 10m³ / h, wide range 0.5 ~ 10m³ / h
  32        32mm, standard range 1.5 ~ 15m³ / h, wide range 0.8 ~ 15m³ / h
40        40mm, standard range 2 ~ 20m³ / h, wide range 1 ~ 20m³ / h
through 50        50mm, standard range 4 ~ 40m³ / h, wide range 2 ~ 40m³ / h
65        65mm, standard range 7 ~ 70m³ / h, wide range 4 ~ 70m³ / h
  80        80mm, standard range 10 ~ 100m³ / h, wide range 5 ~ 100m³ / h
100        100mm, standard range 20 ~ 200m³ / h, wide range 10 ~ 200m³ / h
path 125       

125mm, standard range 25 ~ 250m³ / h, wide range 13 ~ 250m³ / h

150        150mm, standard range 30 ~ 300m³ / h, wide range 15 ~ 300m³ / h
  200        200mm, standard range 80 ~ 800m³ / h, wide range 40 ~ 800m³ / h
class N       Basic type, ± 12V power supply, pulse output, high level ≥8V low level ≤0.8V
A       4 ~ 20mA two-wire current output, remote transmission type
  B       Battery-powered field display
C       On-site display / 4 ~ 20mA two-wire current output
type C1       Field display / RS485 communication protocol
C2       Field display / HART communication protocol
Accuracy class 05      Accuracy class 0.5
10      Accuracy class 1.0
Turbine type W     Wide range turbine
S     Standard turbine
Material S    304 stainless steel
L    316 (L) stainless steel
Explosion proof    Unmarked, non-explosion-proof
E   Explosion-proof type (Exm II CT6 or Exd II BT6)
Pressure Level N General (refer to Table 2)
H ( x) High pressure (refer to Table 2)


Note: DN15 ~ DN40 are usually threaded connections. If you want to use flange connection, please add "(FL)" after "Nominal diameter".
For example, a flange-connected explosion-proof turbine flowmeter is used to measure diesel. The pipeline is DN40. The site needs to display and transmit the current signal remotely. The accuracy is required to be 0.5 grade. It is made of 304 stainless steel. Product model should be: DXLWGY-40 (FL) / C / 05 / S / S / E / H16