Flow meter
LDE split (integrated) electromagnetic flowmeter

LDE split (integrated) electromagnetic flowmeter

Electromagnetic flowmeters are widely used for high-precision measurement of non-impurity oily liquids in the petroleum, chemical, metallurgical, textile, and papermaking industries

  • Measurement medium: any conductive liquid
  • Measuring range: 0.14-113040m³ / h
  • Output signal: 4 ~ 20mA (load resistance 0 ~ 750Ω), pulse / frequency, control level
  • Accuracy grade: 0.5 grade, 1.0 grade
  • Medium temperature:> 180 ℃
  • Explosion-proof grade: Exd [ia] iaqIICT5
  • Protection level: IP65, special order up to IP68
  • User rating:
  • Quality guarantee: The company strictly implements the relevant national warranty regulations, and the product warranty is one year.
  • After-sales service: Jiangsu Dongxiang Instrument provides delivery and provides after-sales service.

Product overview of electromagnetic flowmeter

LDE split (integrated) electromagnetic flowmeter consists of two parts: sensor and converter. It is based on Faraday's law of electromagnetic induction and is used to measure the volume flow of conductive liquids with a conductivity greater than 5 μS / cm. It is an inductive meter that measures the volume flow of conductive media. In addition to measuring the volume flow of general conductive liquids, it can also be used to measure the volume flow of highly corrosive liquids such as strong acids and alkalis, and uniform liquid-solid two-phase suspension liquids such as mud, ore pulp, and pulp. Widely used in petroleum, chemical industry, metallurgy, light textile, papermaking, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, river dredging and other fields to measure diesel oil, lubricants, heavy oil and other oil-free liquids with high precision.
Product features of electromagnetic flowmeter

  • Measurements are not affected by changes in fluid density, viscosity, temperature, pressure and conductivity;
  • There are no flow-blocking components in the measuring tube, no pressure loss, low requirements for straight pipe sections, and unique adaptability to slurry measurement;
  • Reasonable selection of electrodes and lining materials, which have good corrosion resistance and wear resistance;
  • Full digital quantity, strong anti-interference ability, reliable measurement, high accuracy, flow measurement range up to 150: 1;
  • Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage changes, and good anti-EMI performance;
  • 16-bit embedded microprocessor, fast operation speed, high accuracy, programmable frequency and low-frequency rectangular wave roughening, improve the stability of flow measurement and low power consumption;
  • Adopt SMD device and surface mount (SMT) technology, high circuit reliability;
  • There are no moving parts and no choke parts in the pipeline, and there is almost no additional pressure loss in the measurement;
  • At the scene, the range can be modified online according to the actual needs of the user;
  • The measurement result has nothing to do with physical parameters such as velocity distribution, fluid pressure, temperature, density, and viscosity;
  • High-definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to learn and understand;
  • Digital communication signal output such as RS485, RS232, Hart and Modbus Profibus-DP;
  • With self-diagnosis and self-diagnosis functions;
  • Hourly total recording function, which records the total amount of flow in hours, which is applicable to the time-sharing measurement system (optional);
  • There are three totalizers inside which can display the forward cumulative quantity, the reverse cumulative quantity and the difference cumulative quantity. There is a power-down clock inside, which can record 16 power-down times (optional)
  • Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact converter (optional).

Technical parameters of electromagnetic flowmeter


Implementation standards

Electromagnetic flowmeter (JJG1033-2007)

Nominal passage (mm)
(Special specifications can be customized)

Pipeline PTFE lining: DN10-DN600

Pipe rubber lining: DN40-DN2000

Flow direction

Positive, negative, net flow

Range ratio

150: 1

Repeatability error

± 0.1% of measured value

Accuracy class

0.5, 1.0

Measured medium temperature

Conventional rubber lining: -20 ~ + 60 ℃

High temperature rubber lining: -20 ~ + 90 ℃

Teflon lining: -30 ~ + 120 ℃

High temperature type PTFE lining: -20 ~ + 160 ℃

Fixed work stress
(High voltage can be customized)

DN10 ~ DN25≤4.0MPa

DN32 ~ DN150≤1.6MPa

DN200 ~ DN600≤1.0MPa

DN700 ~ DN2000≤0.6MPa

Flow rate range

0.1-15m / s

Conductivity range

Measured fluid conductivity ≥5μs / cm

Signal output

4 ~ 20mA (load resistance 0 ~ 750Ω), pulse / frequency, control level

Communication output

RS485, MODBUS protocol, HART protocol, Profibus-DP protocol

Power supply

220VAC, tolerance 15% or 24VDC, ripple ≤5%

Required straight pipe length

Upstream ≥5DN, downstream ≥2DN

Connection method

The flowmeter and piping are connected by flanges, and the flanges comply with international standards: GB / T9113.1-2000

Explosion-proof grade

Exd [ia] iaqIICT5

Protection class

IP65, special order up to IP68

Ambient temperature

-25 ~ + 60 ℃

Relative humidity

5% ~ 95%

Total power consumption

Less than 20W

Measuring range of electromagnetic flowmeter


0.5

1

2

3

4

5

6

7

8

9

10

10

0.14

0.28

0.57

0.85

1.1

1.4

1.7

2.0

2.3

2.5

2.8

15

0.32

0.64

1.3

1.9

2.5

3.2

3.8

4.5

5.1

5.7

6.3

20

0.57

1.1

2.3

3.4

4.5

5.7

6.8

7.9

9.0

10

11

25

0.88

1.8

3.5

5.3

7.1

8.8

11

12

14

16

17.6

32

1.4

2.9

5.8

8.7

12

14

17

20

twenty three

26

28.9

40

2.3

4.5

9.0

14

18

twenty three

27

32

36

41

45.2

50

3.5

7.1

14

twenty one

28

35

42

49

57

64

70

65

6.0

12

twenty four

36

48

60

72

84

96

107

119

80

9.0

18

36

54

72

90

109

127

145

163

180

100

14

28

57

85

113

141

170

198

226

254

282

125

twenty two

44

88

132

177

221

265

309

353

397

441

150

32

64

127

191

254

318

382

445

509

572

636

200

57

113

226

339

452

565

678

791

904

1017

1131

250

88

177

353

530

707

883

1060

1236

1413

1590

1767

300

127

254

509

763

1017

1272

1526

1780

2035

2289

2545

350

173

346

692

1039

1385

1731

2077

2423

2769

3116

3464

400

226

452

904

1356

1809

2261

2713

3165

3617

4069

4523

450

286

572

1145

1717

2289

2861

3434

4006

4578

5150

5725

500

353

707

1413

2120

2826

3533

4239

4946

5652

6359

7069

600

509

1017

2035

3052

4069

5087

6104

7122

8139

9156

10180

700

692

1385

2769

4154

5539

6924

8308

9693

11708

12463

13847

800

904

1809

3617

5426

7235

9043

10852

12660

14469

16278

18086

900

1145

2289

4578

6867

9156

11445

13734

16023

18312

20602

22891

1000

1413

2826

5652

8478

11304

14130

16956

19782

22608

25434

28260

1200

2035

4069

8139

12208

16278

20347

24417

28486

32556

36625

40694

1400

2769

5539

11708

16617

22156

27695

33234

38773

44312

49851

55390

1600

3617

7235

14469

21704

28938

36173

43407

50642

57876

65111

72346

1800

4578

9156

18312

27469

36625

45781

54937

64094

73250

82406

91562

2000

5652

11304

22608

33912

45216

56520

67824

79128

90432

101736

113040

Product Categories


Product Appearance

Converter form

One-piece

Split

Low power consumption

Implementation standards

JB / T9248-1999

JB / T9248-1999

JB / T9248-1999

Accuracy class

0.5 or 0.2

Level 1 or 0.5

Level 1

Dielectric conductivity

> 5μs / cm

> 5μs / cm

> 5μs / cm

Measurable minimum flow rate

0.1 m / s

0.1 m / s

0.1 m / s

Measurable maximum flow rate

15 m / s

15 m / s

15 m / s

Range ratio

1:20, can be customized

1:20, can be customized

1:20, can be customized

monitor

Standard

Standard

Standard

Signal output

Pulse or 4-20mA

Pulse or 4-20mA

Optional

Power supply

220VAC or + 24VDC

220VAC or + 24VDC

lithium battery

Communication Interface

Optional RS485

Optional RS485

Optional RS485

Protocol

MODBUS, HART, Profibus, etc.

MODBUS, HART, Profibus, etc.

MODBUS, HART, Profibus, etc.

Explosion-proof grade

Exd [ia] qIICT5

Exd [ia] qIICT5

Exd [ia] qIICT5

Protection class

IP65, optional IP68

IP65, optional IP68

IP65, optional IP68

Instrumentation

DN6 ~ DN3000

DN6 ~ DN3000

DN6 ~ DN3000

Installation method

Flange mounting, optional flange clamping

Flange mounting, optional flange clamping

Flange mounting, optional flange clamping

Nominal pressure

1.6MPa or customized

1.6MPa or customized

1.6MPa or customized

Medium temperature

> 180 ℃

> 180 ℃

> 180 ℃

Ambient temperature

-30 ℃ ~ 60 ℃

-30 ℃ ~ 60 ℃

-30 ℃ ~ 60 ℃