Instrument series valve block

DXEF-1 type two valve group

This valve group integrates three types of devices: shut-off, calibration, and exhaust. Its compact structure reduces leakage. The valve has two concave streets, which are used for installation of pressure gauges, pressure sensors or pressure switches. The joint thread can be PT, PF, NPT, G, ZG, R, etc. according to user requirements, please specify when ordering.


DXEF-2 type two valve group

The EF-2 two-valve unit integrates the three devices of cut-off, calibration and exhaust. Its compact structure reduces the number of leaky joints. The valve unit has a concave joint for pressure gauges, pressure sensors or pressure door opening devices. . The joint thread can be PT, PF, NPT, G, ZG, R, etc. according to the user's needs, and the customer can specify when ordering.

DXEF-3 type two valve group

DX1151 type two valve group

The valve integrates the three devices of shut-off, calibration and exhaust. It can be connected to the transmitter through the flange, and its structure is small and easy to install.

DXSS-M2FB two-thread internal valve block


SS-M2F8 internally threaded two valve group is improved on the basis of learning from foreign valve groups. The valve has a small and flexible structure. The valve group and the transmitter are fixed on the bracket through the mounting holes, which solves the problem of integrated field instrumentation. Difficulties in fixing the valve block.

DXYEF-Integrated two valve group

The valve integrates the three devices of shut-off, calibration and exhaust, and can be directly connected to the transmitter through the flange. The structure is compact and the leak-proof joint is reduced.

DX1151 three valve group

This valve group is installed with 1151 series capacitive differential pressure transmitters. It is used to introduce signals from the pressure point to the positive and negative measurement rooms of the 1151 series differential pressure transmitters, so that the pressure points are connected to or disconnected from the measurement room. Direct connection to transmitter via flange.

Serial number
Nominal pressure
PN
Nominal diameter
DN
proper temperature
Body material
1
20MPa
5
-20 ~ 440
35 #
2
-70 ~ 240
1Cr18Ni9Ti
3
40MPa
-20 ~ 440
35 #
4
-70 ~ 240
1Cr18Ni9Ti

DXYSF integrated three valve group

YSF integrated three valve group

Note: The valve group can be directly fixed on the transmitter, and is used to introduce signals from the pressure point to the positive and negative measurement room of the differential pressure transmitter, so that the pressure point is connected to or disconnected from the measurement room. It can be installed and used with various pneumatic or electric differential pressure (pressure) transmitters at home and abroad.

Performance specifications Nominal pressure: PN2.5, PN4, PN6.4, PN16, PN32MPa
Nominal diameter: DN5-DN25
Applicable temperature: -70 ℃ -440 ℃
Applicable medium: oil, water, gas and other non-corrosive or corrosive media Manufacturing materials: 20 #, 1Cr18Ni9Ti, 0Cr18Ni12Mo2Ti, 304, 316L, etc.
* Piping: copper pipe Φ6, Φ8, Φ10 steel pipe Φ12, Φ14, Φ16, Φ18

DXSS-M3F8-FL flange three-valve

The valve group is composed of high and low pressure valves and balance valve groups, and its function is the same as QFF3. The connection method of the pressure point is a card sleeve type or a welding type, and it is directly connected to the transmitter through a flange, which reduces leakage points and facilitates installation.

DXSF-1 type three valve group

This valve can be installed on the arterial pipeline where the flow test instrument needs to be transmitted remotely. It consists of two pressure taking valves and a balance valve, which facilitates the establishment of the instrument control circuit.

DXSF-2 type three valve group

The valve group can be directly installed and used in combination with differential pressure, pressure instruments or transmitters. The differential pressure port can also be directly connected to the pressure pipe joint. The center distance between the two joints is 35mm.

DXSF-3 type three valve group

This valve group can be directly installed and used with differential pressure, pressure instruments or transmitters. The differential pressure port is connected to the pressure guiding tube through a waist flange. The center distance between the two joints is 54mm.

DXSS-M3F8 three-valve internal thread

The valve group is designed by referring to the three valve group in Singapore. It has a compact structure, good sealing performance, easy installation and use, and the valve group comes with adjusting holes, which can be directly fixed on the mounting bracket to facilitate disassembly.

DXQFF3 type three valve group

QFF3 type three valve group is composed of high and low pressure valve and balance valve group, which is used together with differential pressure transmitter. Its role is to connect or disconnect the positive and negative measurement rooms of the differential pressure transmitter to the pressure point, or to disconnect and conduct the positive and negative pressure measurement room. The pressure and pressure points are directly connected to the steel pipe. Welding, or other connection methods can be used.

DXWF1 / 2 type five valve group

WF1 / 2 type five-valve unit: This valve is suitable for all kinds of imported instrumentation devices. It is installed with various differential pressure, flow, liquid level and other transmitters. The blowdown) valve combination is a rest. When working, the two sets of check valves and the balance valve are closed. For inspection, just cut off the high and low valves, open the balance valve and open the two check valves, and then close the balance valve. The transmitter can be calibrated or balanced online.

No.
Nominal pressure PN
Nominal diameter DN
Applicable temperature ℃
Body Material Material
1
20MPa
5
-20--440
35 "
2
20MPa
5
-70--240
1Cr18Ni9Ti
3
40MPa
5
-20—440
35 "
4
40MPa
5
-70--240
1Cr18Ni9Ti

DXYWF integrated five valve group

The valve group can be installed on the pulsation tube when the flow meter is transmitted remotely. It consists of two pressure taking valves, a balance valve and two discharge, cleaning and calibration valves, which facilitates the establishment of the instrument control circuit. Two drain valves allow the meter to drain any corrosive fluid without having to be removed from the installation position.

DX1151 type five valve group

Type 1151 five-valve unit is suitable for installation in a variety of imported instrumentation devices. It is installed with a variety of differential pressure, flow, and liquid level transmitters. Integrated, the two sets of calibration valves and balance valves are closed during work. For inspection, as long as the high and low pressure valves are cut off, the balance valve and the two calibration valves are opened, and then the transmitter can be adjusted after closing the balance. Checksum balance.

DXSS-M5F8-FL flange five-valve

The SS-M5F8-FL flange five-valve unit is suitable for various imported instrumentation devices, and is installed with various differential pressure, flow, and liquid level transmitters. It consists of high and low pressure valves, balance valves, and two calibration ( The blowdown valve is combined into one body. When working, the two sets of calibration valves and the balance valve are closed. For calibration, just cut off the high and low pressure valves, open the balance valve and open the two calibration valves, and then close the balance The transmitter can be calibrated and balanced online.