⎝⎛星力捕鱼⎞⎠

⎝⎛星力捕鱼⎞⎠ page Company Profile ⎝⎛星力捕鱼⎞⎠ Product center Quality system marketing network After sales service Recruitment contact us
Flow meter series
Temperature instrument series
Pressure instrument series
Calibration instrument series
Level instrument series
Digital display instrument series
Transmitter instrument series
Wire and cable series
Bridge instrument cabinet series
Pipe fitting valve series

Address: Xiongyi, Jinhe Road, Jinhu County, Jiangsu Province
Lunan
Phone: 0517-86900901
0517-86900921
0517-86900920
Fax: 0517-86900902
Postcode: 211600
http://zzyfwh.com
Email: chinadongxiang@163.com
Wire and Cable
KVVP, RVVP series shielded signal cable

use:
Shielded signal cable (shielded signal cable) is suitable for connection cables of control, monitoring circuits and protection circuits of power appliances, instruments and telecommunications equipment with rated voltage U0 / U 450 / 750V and below. It is mainly used to prevent electromagnetic interference and requires shielding. Place.
Product standards
GB9330-1998
III. Conditions of use The long-term allowable working temperature of the cable guide is 70 ° C, and the bending radius of the cable is as follows:
1. The cable without armor should be no less than 6 times the outer diameter of the cable.
2. Cables with armored or copper tape shield structure should not be less than 12 times the outer diameter of the cable.
3. A flexible cable with a shield structure should be less than 6 times the outer diameter of the cable.
Model, name and scope of use
1. Polyethylene insulated PVC sheathed shielded signal (control) cable
KVVP copper core PVC insulated and sheathed braided shielded control cable is laid in indoor, cable trench, pipeline and other fixed places where shielding is required
KVVRP copper core PVC insulated and sheathed braided shielded control flexible cable laying indoors requires flexibility, shielding, etc.
KVVP2 copper core PVC insulated and sheathed copper tape shielded control cables are laid indoors, cable trenches, pipes and other fixed places where shielding is required
KVVP3 copper core PVC insulated and sheathed aluminum-plastic composite tape shielded control cable is laid in indoor, cable trench, pipeline and other fixed occasions where shielding is required
KVVP-22 Copper core PVC insulated and sheathed braided shielded steel tape armored control cable is installed indoors, in cable trenches, pipes, directly buried and can withstand large mechanical external forces and other fixed occasions
KVVP2-22 Copper core PVC insulated and sheathed steel tape armored control cables are installed indoors, in cable trenches, pipelines, directly buried and other fixed places that can withstand large mechanical external forces.
2.PE insulated PVC sheathed shielded power cable:
Model name use range
RVV core PVC insulated and sheathed soft power cables are laid in fixed places such as indoors, cable trenches, pipes, etc.
RVVP copper core PVC insulated and sheathed braided shielded soft power cable is laid indoors, cable trenches, pipes and other fixed occasions where shielding is required
RVVP2 copper core PVC insulated and sheathed copper tape shielded soft power cable is laid indoors, cable trenches, pipes and other fixed occasions where shielding is required
RVVP3 copper core PVC insulated and sheathed aluminum-plastic composite tape shielded soft power cable is laid indoors, cable trenches, pipes and other fixed occasions where shielding is required
RVVP-22 Copper core PVC insulated and sheathed braided shielded steel tape armored soft power cable is installed indoors, in cable trenches, pipelines, directly buried and other fixed occasions that can withstand large external mechanical forces
RVVP2-22 Copper core PVC insulated and sheathed steel tape armored soft power cable is installed indoors, in cable trenches, pipelines, directly buried and other fixed occasions that can withstand large mechanical external forces.