Compensation wire

Compensation wire (compensation cable) refers to a pair of insulated wires with the same nominal value as the thermoelectromotive force of the thermocouple to which they are matched within a certain temperature range. Use them to connect the thermocouple and the temperature display control instrument to Compensate for errors caused by temperature changes where they connect to the thermocouple.
Compensation wire (compensation cable) is suitable for single-point or multi-point connection of automatic temperature measuring instruments in electric power, metallurgy, petroleum, chemical, light textile and other industries, as well as national defense, scientific research and other departments.
Product Standards:
Compensation wire: GB / T4989-94
Use characteristics:
Operating temperature: heat-resistant grade: -65 ℃ ~ + 200 ℃ and -65 ℃ ~ + 260 ℃;
Normal grade: -40 ℃ ~ + 70 ℃ and -40 ℃ ~ + 105 ℃;
Minimum bending radius: Compensating wire: not less than 8 times the outer diameter of the conductor;
Compensation cable: no less than 12 times the outer diameter of the cable when armored, no less than 6 times the outer diameter of the cable without armor. Main technical indicators:
Model, alloy wire material and insulation color

model

Thermocouple
Index number

With thermocouple

Compensation wire alloy wire

Insulation coloring

positive electrode

negative electrode

positive electrode

negative electrode

BC

B

Platinum Rhodium 30- Platinum Rhodium 6

copper

copper

gray

SC

S

Platinum Rhodium 10- Platinum

SPC (copper)

SNC (copper nickel 0.6)

red

green

RC

R

Platinum Rhodium 13- Platinum

RPC (copper)

RNC (copper nickel 0.6)

red

green

KCA

K

Nichrome-NiSi

KPCA (iron)

KNCA (copper nickel 2)

red

Blue

KCB

KPCB (copper)

KNCB (copper nickel 4)

red

Blue

KX

KPX (Ni-Cr 10)

KNX (nickel silicon 3)

red

black

NC

N

NiCrSi-NiSi

NPC (iron)

NNC (copper nickel 18)

red

gray

NX

NPX (Ni-Cr 14 Silicon)

NNX (nickel silicon 4)

red

gray

EX

E

Nickel silicon-nickel silicon

EPX (Ni-Cr 10)

ENX (copper-nickel 45)

red

Brown

JX

J

Iron-copper nickel

JPX (iron)

JNX (copper nickel 45)

red

purple

TX

T

Copper-Copper Nickel

TPX (copper)

TNX (copper-nickel 45)

red

White

WC3 / 25

WRe3-WRe25

Tungsten-Tungsten Rhenium 25

WPC3 / 25

WNC3 / 25

red

yellow

WC5 / 26

WRe5-WRe26

Tungsten Tungsten 5-Tungsten Tungsten 26

WPC5 / 26

WNC5 / 26

red

Orange

Use classification and cover color

Use classification

Accuracy grade and mark

Cover coloring

Ordinary

Precision

Ordinary

Precision

General use

G

/

S

black

gray

Heat resistant

H

/

S

black

yellow

Tolerance and reciprocating resistance

Compensation lead type

Reciprocating resistance Ω / m at 20 ℃ is not greater than

0.2mm2

0.5mm2

1.0mm2

1.5mm2

2.5mm2

NC or BC

0.25

0.10

0.05

0.03

0.02

KCA

3.50

1.40

0.70

0.47

0.28

KCB

2.60

1.40

0.70

0.47

0.28

KX

5.50

2.20

1.10

0.73

0.44

EX

6.25

2.50

1.10

0.73

0.44

JX

6.25

2.50

1.25

0.83

0.50

TX

3.25

1.30

0.65

0.43

0.26

NC

3.75

1.50

0.75

0.50

0.30

N

7.15

2.86

1.43

0.95

0.57

WC3 / 25

0.50

0.20

0.10

0.07

0.04

WC5 / 26

0.50

0.20

0.10

0.07

0.04

Insulation resistance (20 ℃): PVC insulation is not less than 25MΩ.Km; FEP or PEA insulation is not less than 100MΩ.Km.
Flame retardant properties: Passed Class A (tested according to GB12666.5-90)
specification:

Structure \ section mm2
0.2
0.5
1.0
1.5
2.5
Number of core pairs
Single strand core mm
1 / 0.52
1 / 0.80
1 / 1.13
1 / 1.37
1 / 1.76
1 pair of wires
Cable 2-37 pairs
Stranded core mm
7 / 0.20
7 / 0.30
7 / 0.43
7 / 0.52
19 / 0.41

Delivery requirements The short lead delivery of the compensation lead and compensation cable is not less than 100 meters and the allowable length is not less than 20 meters.
Delivery of cables of any length according to mutual agreement

Compensation wire series products: shielded compensation wire; high-temperature compensation wire; intrinsically safe compensation wire; dedicated thermocouple compensation wire.