Wire and Cable
Compensation wire and cable for thermocouple

The function of the thermocouple with the compensation wire is to extend the cold end of the hot electrode, that is, the mobile thermocouple, and connect it with the display instrument to form a temperature measurement system. This product adopts GB / T 4989-94 "Compensation wire for thermocouple" national standard (equivalent to IEC584-3 "Thermocouple part III-Compensation wire" international standard). And adopt the new continuous continuous extrusion process, so that the product has excellent acid resistance, alkali resistance, wear resistance and non-combustible properties, can be immersed in oil and water for long-term use. The use temperature is -60-205-260 ° C, which belongs to the advanced international level. The products are mainly used in various temperature measuring devices and have been widely used in petroleum, chemical, metallurgy, power and other departments.
Model indication

Main Specifications:
Compensation wire model is divided into SC, KC, KX, EX, JX, TX, NC according to the product type
Among them: a) the first letter of the model corresponds to the graduation number of the thermocouple;
b) The letter "X" indicates an extended compensation lead (type);
c) The letter "C" indicates a compensation type compensation lead (type).
Note: SC type compensation wire can be used with R type indexing thermocouple

Product code (marking)

Equipped with thermoelectric
Even division
General use (G)
Product number
Heat resistant (H)
Product number
Ordinary Precision grade (S) Ordinary Precision grade (S)
S SC-G SC-GS SC-H -
N NC-G NC-GS NC-H NC-HS
K NC-G NC-GS NC-H -
KC2-G KG2-GS KC2-H KC2-HS
KX-G KX-GS KX-H KX-HS
E EX-G EX-GS EX-H EX-HS
J JX-G JX-GS JX-H JX-HS
T TX-G TX-GS TX-H TX-HS

Compensation wire alloy wire and insulation color

Compensation number
Line model
Equipped with thermoelectric
Even division
Compensation wire alloy wire Insulation
Coloring
positive electrode negative electrode positive electrode negative electrode
SC S (platinum chromium 10-platinum) SPC (copper) SNC (copper nickel) red green
NC N (nickel chromium silicon-nickel silicon) NPC (Iron) NNC (copper nickel) red yellow
KC K (copper-constantan) KPC (copper) KNC (copper nickel) red blue
KX K (Ni-Cr-Ni-Si) KPX (nickel chromium) KNX (copper nickel) red black
EX E (Ni-Cr-Cu-Ni) EPX (nickel chromium) ENX (copper nickel) red Brown
JX J (Iron-Copper-Ni) JPX (iron) JNX (copper nickel) red purple
TX T (copper-copper-nickel) TPX (copper) TNX (copper nickel) red White

Compensate the thermoelectric potential and tolerance of the wire
Thermal potential and tolerance (μV) Thermocouple test
End temperature (℃)
100 ℃
100 ℃
Thermoelectric potential
(standard value)
Tolerance Thermoelectric potential
(standard value)
Tolerance
Ordinary Precision (S) Ordinary Precision (S)
SC or RC 645 ± 60 (± 5.0 ℃) ± 30 (± 2.5 ℃) 1440 ± 60 (± 5.0 ℃) - 1000
KCA 4095 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 8137 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 900
KCB 4095 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 8137 - - 900
KX 4095 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 8137 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 900
NC 2774 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 5912 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 900
NX 2774 ± 200 (± 2.5 ℃) ± 60 (± 1.5 ℃) 5912 ± 100 (± 2.5 ℃) ± 60 (± 1.5 ℃) 900
EX 6317 ± 60 (± 2.5 ℃) ± 120 (± 1.5 ℃) 13419 ± 200 (± 2.5 ℃) ± 120 (± 1.5 ℃) 600
JX 5268 ± 140 (± 2.5 ℃) ± 85 (± 1.5 ℃) 10777 ± 140 (± 2.5 ℃) ± 85 (± 1.5 ℃) 500
TX 4277 ± 60 (± 1.0 ℃) ± 30 (± 0.5 ℃) 9285 ± 90 (± 1.5 ℃) ± 48 (± 0.8 ℃) 300

Core cross-section, number of strands, single wire diameter, insulation layer, sheath and outer diameter of compensation wire:
Use classification Nominal section (mm2) Single wire core Multi-strand flexible core (R) Insulation layer thickness (mm) Sheath thickness (mm) Maximum outer diameter (mm)
Wire core number (root) Single wire diameter (mm) Wire core number (root) Single wire diameter (mm) Flat type Shielded Flat Type
Single wire core Multi-strand core Single wire core Multi-strand core
General (G) 0.2 1 0.5 7 0.2 0.4 0.7 3.0x4.6 3.1x4.8 3.8x5.4 3.9x5.6
0.5 1 0.80 7 0.30 0.5 0.8 3.7x6.4 3.9x6.6 4.5x7.2 4.7x7.4
1.0 1 1.13 7 0.43 0.7 1.0 5.0x7.7 5.1x8.0 5.8x8.5 5.9x8.8
1.5 1 1.37 7 0.52 0.7 1.0 5.2x8.3 5.5x8.7 6.0x9.1 6.3x9.6
2.5 1 1.76 19 0.41 0.7 1.0 5.7x9.3 5.9x9.8 6.5x10.1 6.7x10.7
Heat resistant (H) 0.2 1 0.5 7 0.2 0.4 0.3 2.3x4.0 2.4x4.2 3.1x4.8 3.2x5.0
0.5 1 0.80 7 0.3 0.4 0.3 2.9x5.0 3.0x5.2 3.7x5.5 3.8x6.0
1.0 1 1.13 7 0.43 0.4 0.3 3.5x5.7 3.7x6.1 4.3x6.5 4.5x6.9
1.5 1 1.37 7 0.52 0.4 0.3 4.0x6.5 4.2x6.9 4.8x7.3 5.0x7.7
2.5 1 1.76 19 0.41 0.4 0.3 4.5x7.3 4.8x7.9 5.3x8.1 5.6x8.7
Order delivery instructions:
1. The length of delivery is 100m or an integral multiple. Delivery of short lengths of wire not less than 20m is allowed, but the quantity must not exceed 10% of the total delivery.
2. Compensation cable for thermocouple for multi-point temperature measurement.
3. If the user has special needs, he can indicate in the order contract.