Flow meter series
Temperature instrument series
Pressure instrument series
Calibration instrument series
Level instrument series
Digital display instrument series
Transmitter instrument series
Wire and cable series
Bridge instrument cabinet series
Pipe fitting valve series

Address: Xiongyi, Jinhe Road, Jinhu County, Jiangsu Province
Lunan
Phone: 0517-86900901
0517-86900921
0517-86900920
Fax: 0517-86900902
Postcode: 211600
http://zzyfwh.com
Email: chinadongxiang@163.com
Wire and Cable
Intrinsically safe signal control cable

This product is widely used in chemical and petrochemical industries in medium-level explosive environment automation control systems, monitoring circuits and protection circuits, as a weak signal transmission in various intrinsically safe circuits; in addition to the characteristics of small distribution parameters, this product also uses Strengthen the shielding layer, so that it has excellent resistance to external electromagnetic field interference, radio frequency interference and other performance.

I. Production Implementation Standards
Enterprise Standards II. Conditions of Use
① Rated voltage Uo / U: 300 / 500V.
② Maximum working temperature: general type does not exceed 70 ℃; the maximum with 105 after the model does not exceed 105 ℃
③Minimum ambient temperature: fixed laying: -40 ° C, non-fixed laying: -15 ° C.
④ Minimum bending radius: The cable without armor should be no less than 6 times the outer diameter of the cable; the cable with armor should not be less than 12 times the outer diameter of the cable.
Product model, name and conditions of use

model name Conditions of Use
ia-K2YV Intrinsically safe PE insulated, PVC sheathed two-core twisted shielded control cable 1.Fixed laying indoors, in cable trenches or pipes
2. Working temperature of cable: -15 ℃ ~ + 105 ℃
3. The laying temperature of the cable is not lower than 0 ℃, and the bending radius is not less than 10 times the outer diameter of the cable.
4.Rated voltage 300 / 350V
5. It should be laid separately or effectively isolated from non-intrinsically safe cables.
ia-K2YVR Intrinsically safe PE insulated, PVC sheathed two-core twisted shielded control flexible cable
ia-K2YV (EX) Intrinsically safe PE insulated, PVC sheathed two-core stranded shielded cable
ia-K2YV (EX) R Intrinsically safe PE insulated, PVC sheathed two-core twisted shielded flexible cable
ia-K3YV Intrinsically safe PE insulated, PVC sheathed three core twisted shielded control cable
ia-K3YVR Intrinsically safe PE insulated, PVC sheathed three core twisted shielded control flexible cable
ia-K3YV (EX) Intrinsically safe PE insulated, PVC sheathed three core twisted shielded instrument cable
ia-K3YV (EX) R Intrinsically safe PE insulated, PVC sheathed three core twisted shielded flexible cable
Note: ① This product can be wrapped with copper / aluminum composite film. The P in the model should be changed to: P2 for copper-plastic composite tape and P3 for aluminum-plastic composite tape.
② The steel belt armored intrinsically safe signal control cable can be produced as required. The code "22" should be added to the lower right corner of the model, such as ia-K2YV22
③ If the temperature resistance is 105 ° C, it should be indicated after the model, such as ia-K2YV105 (70 ° C resistance can be omitted)
④ The production range of the second line group is 1 to 37 pairs, and the production range of the third line group is 1 to 24 pairs. Only the logarithms listed in the table are recommended. Examples: copper core R structure, polyethylene insulation, second line group, polyethylene sheath, plus points. Shielding and total shielding 10 pairs of 1.0m㎡ are expressed as: ia-K2YVPR10 × 2 × 1.0m㎡
Fourth, the conductor structure

Nominal cross section of core (m㎡)

Copper core

Number / diameter (mm)

Class A

Class B

R class

0.5

1 / 0.8

7 / 0.30

16 / 0.2

0.75

1 / 0.97

7 / 0.37

24 / 0.2

1.0

1 / 1.13

7 / 0.43

32 / 0.2

1.5

1 / 1.37

7 / 0.52

30 / 0.25

2.5

1 / 1.76

7 / 0.68

49 / 0.25

Five, performance parameters

Serial number

Performance items

unit

Performance

0.75

1.0

1.5

2.5

1

DC resistance of conductor

≤Ω / km

24.5

18.1

12.1

7.41

26.0

19.5

13.3

7.98

2

Working capacitor

≤pF / m

90

3

Distributed inductance

≤uH / m

1.2

4

Resistant to external magnetic interference

≤mv

5

5

Anti-static interference

≤v

1

6

Anti-radio frequency interference

≤dB

60

7

Insulation resistance (20 ℃)
(Core-to-core, core-to-screen)

≥MΩ / · km

500

8

Voltage test (core-to-core, core-to-screen)

1kv / 5min

No breakdown

Six, cable manufacturing length
The delivery length of the cable is not less than 100 meters, and any length of cable is allowed according to the agreement between the two parties.

Our model

ia-K2YVR ia-K2YV

ia-K3YVR ia-K3YV

Other models

KJYYVPL

KVVia

IA-K2YVP

KVVPL

ia-K2YV (EX)

IA-KJVVPL

IA-K2VPZV

ia-K3YV (EX)