technical article
Main reasons for errors in pressure gauges
2011-6-2 8:11:45

Main reasons for errors in pressure gauges

Pressure gauge is a device used to realize pressure measurement in production and life. The most important thing in the use of pressure gauge is the accuracy indicated by the pressure gauge . The pressure gauge indicates whether the indication is accurate or not. In addition to some factors of the pressure gauge itself, external factors will also affect the indication result.
1. The pressure gauge is affected by vibration
Pressure gauges also have inaccurate indications in a vibrating environment. Severe vibrations will directly cause deformation of the elastic elements of the pressure gauge, affecting the sensitivity and accuracy of the pressure gauge and the user's reading of the indicated value of the pressure gauge. The anti-vibration measures of the pressure gauge are mainly to install a buffer device and a shock absorbing device.
2. The pressure gauge is affected by overload
The overload operation of the pressure gauge does not just mean that the indicated value of the pressure gauge reaches the maximum of the scale. In fact, when the position exceeds 2/3 of the full scale, the elastic element of the pressure gauge is already in the near limit state. The pressure gauge works for a long time under an overloaded state, and its internal elastic elements such as spring tubes and diaphragms will weaken or even lose their elasticity because of a long-term or near-limit deformation state, and eventually undergo permanent deformation.
3 , the pressure gauge is affected by temperature
The pressure measurement of a pressure meter mainly depends on its elastic components such as spring tubes. In high or low temperature environments, the elastic components of the pressure instrument will deform under the effect of temperature, especially for long-term work in high-temperature media. In a pressure gauge, the elastic element may be permanently deformed, which will cause an error in the display of the pressure gauge.
In the use of pressure gauges, it is necessary to minimize the effect of temperature on the indicated value of the pressure gauge. The most direct and effective method is to avoid the pressure gauge to work in abnormal temperature environment. If it cannot be avoided, the pressure gauge should be protected from high temperature or cold. For example, install condensing device or insulation device for pressure gauge.