⎝⎛星力捕鱼⎞⎠

⎝⎛星力捕鱼⎞⎠ page Company Profile ⎝⎛星力捕鱼⎞⎠ Product center Quality system marketing network After sales service Recruitment contact us
Flow meter series
Temperature instrument series
Pressure instrument series
Calibration instrument series
Level instrument series
Digital display instrument series
Transmitter instrument series
Wire and cable series
Bridge instrument cabinet series
Pipe fitting valve series

Address: Xiongyi, Jinhe Road, Jinhu County, Jiangsu Province
Lunan
Phone: 0517-86900901
0517-86900921
0517-86900920
Fax: 0517-86900902
Postcode: 211600
http://zzyfwh.com
Email: chinadongxiang@163.com
Industry Information
Plastic tube rotor flowmeter for daily use
2012-2-28 16:00:07

安装(1) 安装前,应把仪表内的光洁支撑物用工具尖嘴钳轻轻把它取出,然后重新把它安装好,在安装时,要注意橡胶圈是否装在接管的槽内,以防漏水. LZS plastic tube rotor flowmeter installation (1) Before installation, the smooth support in the instrument should be gently removed with tool nose pliers, and then reinstalled. When installing, pay attention to whether the rubber ring is installed in the Take over the tank to prevent water leakage.
(2) The interface of the flowmeter can be matched with ABS plastic pipe or PVC plastic pipe with special dewatering adhesive connection. It can also be connected by plastic method and then connected with metal flange.
(3) The flowmeter must be installed vertically, without obvious tilt, and its installation height should be convenient for reading the float. When reading, the line of sight and the float should be horizontal. (General standard: The best flow rate required is 50% to 70% of the maximum flow rate of the flowmeter. Try not to use the highest number.)
(4) At the upstream and downstream of the meter, the inlet and outlet of the meter shall ensure a straight pipe section with 5 times the meter diameter.
(5) The pressure of the measured fluid must be stable. If the fluid pressure is unstable, it will cause the float to fluctuate and cannot be measured correctly. A buffer or a setter should be set upstream of the flow meter.


日常使用: LZS plastic tube rotor flowmeter daily use:
When the flowmeter is in use, slowly open the upstream valve to full open, and then use the regulating valve downstream of the flowmeter to adjust the flow.
(Prevent the float from suddenly impacting upwards and damaging the meter, and avoid sudden changes in the measured body temperature. If a leak is found in the flowmeter during use, the seal ring is generally misplaced or invalid, and it should be corrected or replaced.)
When the flowmeter is stopped, the upstream valve should be closed slowly first, and then the flow regulating valve downstream of the flowmeter should be closed.

Principle and structure of plastic tube rotor flowmeter


的主要测量元件为一根小端向下,大端向上垂直安装的锥形塑料管及其在内可以上下移动的浮子。 The main measuring element of the plastic tube rotor flowmeter is a conical plastic tube with a small end facing downward and a large end facing upward, and a float that can move up and down inside. When the fluid flows through the conical plastic tube from bottom to top, a pressure difference is generated between the upper and lower parts of the float, and the float rises under the action of this differential pressure. When the force that causes the float to rise is equal to the combined forces of gravity, buoyancy, and viscous force, the float is in an equilibrium position. Therefore, there is a certain proportional relationship between the flow rate of the fluid flowing through the flowmeter and the rising height of the float, that is, the flow area of the flowmeter. The position height of the float can be used as a flow measurement.