⎝⎛星力捕鱼⎞⎠

⎝⎛星力捕鱼⎞⎠ page Company Profile ⎝⎛星力捕鱼⎞⎠ Product center Quality system marketing network After sales service Recruitment contact us
Flow meter series
Temperature instrument series
Pressure instrument series
Calibration instrument series
Level instrument series
Digital display instrument series
Transmitter instrument series
Wire and cable series
Bridge instrument cabinet series
Pipe fitting valve series

Address: Xiongyi, Jinhe Road, Jinhu County, Jiangsu Province
Lunan
Phone: 0517-86900901
0517-86900921
0517-86900920
Fax: 0517-86900902
Postcode: 211600
http://zzyfwh.com
Email: chinadongxiang@163.com
Industry Information
Verabar flowmeters always stay ahead with their unique advantages
2012-3-21 10:05:33

Verabar Flowmeter Operation and Maintenance Guide
以其独特的优势在插入式流量计中始终保持领先的优势。 With its unique advantages, Verabar flowmeters always maintain a leading position in plug-in flowmeters. Verabar flowmeter is basically suitable for the measurement of all pipeline specifications on the site. The application on large-diameter pipelines shows even more advantages. It is suitable for measuring the flow of various liquids, gases, and steam, especially ultra-low temperature, high temperature, high pressure, and humid fluid Measurement of media. However, while the application is being promoted, customers will also encounter the same questions about how to maintain. The following is a rough summary of the work and simple maintenance of Verabar flowmeters before commissioning: 1. Check the installation of the flowmeters: complete After the Verabar flowmeter is installed, it must be carefully inspected. It is required that the welding is firm, the direction is correct, and there is no leakage in the pressure test. 2. Instrument calibration: Read the manual of the intelligent flow totalizer carefully. According to the calculation book attached to the Verabar flowmeter, set the parameters in the intelligent flow totalizer correctly to ensure that the totalizer can correctly calculate and display the flow. If you are directly on the computer, you need to set the input data format and corresponding compensation methods in the computer. 3. Instrument wiring is correct: Verabar flowmeter, differential pressure transmitter, and flow totalizer constitute a measurement system. Please check repeatedly to make sure that it is correct. Rear can be put into operation. 4. System warm-up: After the preparation for commissioning is completed, the measured medium fills the process pipeline, and the Verabar flowmeter is temporarily closed. At this time, the balance valve of the three valve group should be opened, and the high pressure valve and low pressure valve should be closed. status. Power on the instrument and warm up for 15 minutes. 5. System operation: After the preheating is completed, open the high-pressure valve and low-pressure valve of the three-valve group, fill the differential pressure transmitter with the measured medium, open the drain valve behind the differential pressure transmitter, and quickly discharge the dirty liquid or gas. Close the blowdown valve and then close the balance valve of the three-valve group. The transmitter will enter the measurement state and the flow totalizer will also enter the working state to display the medium flow in the pipeline. 可交付使用 If the above work is successful and the commissioning is completed, the Verabar flowmeter can be delivered for use.

安装注意事项 Verabar flowmeter installation precautions
1. Measuring liquid: Verabar flowmeter is installed within 160 ° below the pipeline; install gas, Verabar is installed within 160 ° above the pipeline; measuring steam: Verabar is installed below the pipeline; for vertical pipelines, it can be installed around the vertical Verabar is installed in any direction of the pipe at 360 °, and single or double-sided support is selected according to the pipe diameter and the medium. 2. When the upstream and downstream straight pipe sections are not long enough, install a Verabar flowmeter 2 times the pipe diameter after the pipe bend. 3. To facilitate cleaning and maintenance of the flowmeter in the future, a bypass pipe should be installed. 4. If there is vibration in the measuring pipe, there should be fixed supports on both sides of the flow meter. 5. The pressure of the pipeline where the flow meter is installed must not exceed the rated maximum working pressure. 6. When the impulse tube leaks, smaller particles in the high pressure balance area of the probe may enter the pressure taking hole. When the pipeline is stopped, small particles may enter the pressure taking tube due to the Brownian motion of the molecule. Clean the probes regularly. 7. Regularly check whether the body of Verabar is bent, deformed, and whether the valve and connection flanges, joints are leaking or blocked. Use iron wire to clear the pressure-receiving pipeline and replace the flange gasket. 8. When measuring gas and steam, the measurement accuracy will be affected by temperature and pressure changes, so compensation should be considered. 9. Each Verabar probe needs to be analyzed for differential pressure, pressure, and structural strength according to fluid conditions before use, and to determine the range of the differential pressure transmitter based on the calculated differential pressure.